Research and development of the pulse acquisition system and the pulse biomimetic reproduction system

  • Kai YI ,
  • Yunjing MA ,
  • Shen GUO ,
  • Heng LIU ,
  • Bin XU
Expand
  • 1 the First Clinical College, Liaoning University of Traditional Chinese Medicine, Shenyang 110000, China
    2 Research and Development Department, Shenyang Traditional Chinese Medicine Intelligent Medical Equipment Industry Technology Research Institute, Shenyang 110000, China

Received date: 2023-12-22

  Accepted date: 2024-04-15

  Online published: 2025-01-10

Supported by

Key R&D Plan of Liaoning Province(202000357-JH13/103);Construction of Liaoning Traditional Chinese Medicine Industry Technology Innovation Research Institute; National Key Research and Development Plan Special Project(2019JH2/10300040)

Abstract

The paper is an introduction to the front-end pulse acquisition and the back-end pulse biomimetic reproduction system. This system is capable of faithfully replicating the complete pulse waveform collected at the front end. Traditional Chinese Medicine (TCM) practitioners analyze and diagnose the pulse patterns at the replication end. Meanwhile, the obtained pulse waveforms are analyzed and learnt by a neural network based on key diagnostic points in TCM pulse taking, which enables the determination of the corresponding relationships between different pulse waveforms and various pulse patterns in TCM pulse taking. With the support of clinical samples, an auxiliary diagnostic system for TCM pulse patterns ensures the accuracy of pulse pattern replication.

Cite this article

Kai YI , Yunjing MA , Shen GUO , Heng LIU , Bin XU . Research and development of the pulse acquisition system and the pulse biomimetic reproduction system[J]. Journal of Traditional Chinese Medicine, 2025 , 45(1) : 213 -220 . DOI: 10.19852/j.cnki.jtcm.2025.01.021

References

1. Lee JY, Jang M, Shin SH. Study on the depth, rate, shape, and strength of pulse with cardiovascular simulator. Evid Based Complement Alternat Med 2017; 2017: 2867191.
2. Hsieh TC, Wu CM, Tsai CC, Lo WC, Wang YM, Smith S. Portable interactive pulse tactile recorder and player system. Sensors (Basel) 2021; 21: 4339.
3. Tang ACY. Review of Traditional Chinese Medicine pulse diagnosis quantification. Comp Therap Contemp Healthcare 2012; 61-80.
4. Chu YW, Luo CH, Chung YF, Hu CS, Yeh CC. Using an array sensor to determine differences in pulse diagnosis — three positions and nine indicators. Eur J Integr Med 2014; 6: 516-23.
5. Tyan CC, Liu SH, Chen JY, Chen JJ, Liang WM. A novel noninvasive measurement technique for analyzing the pressure pulse waveform of the radial artery. IEEE Trans Biomed Eng 2008; 55: 288-97.
6. Jin C, Xia C, Zhang S, Wang L, Wang Y, Yan H. A wearable combined wrist pulse measurement system using airbags for pressurization. Sensors (Basel) 2019; 19: 386.
7. Kaisti M, Panula T, Lepp?nen J, et al. Clinical assessment of a non-invasive wearable MEMS pressure sensor array for monitoring of arterial pulse waveform, heart rate and detection of atrial fibrillation. NPJ Digit Med 2019; 2: 39.
8. He D, Zheng L, Liu J, Geng N, Dejun G, Xu L. Variation of radial pulse wave contour influenced by contact pressure. Annu Int Conf IEEE Eng Med Biol Soc 2014; 2014: 5635-8.
9. Chen C, Li Z, Zhang Y, Zhang S, Hou J, Zhang H. A 3D wrist pulse signal acquisition system for width information of pulse wave. Sensors (Basel) 2019; 20: 11.
10. Nie J, Ji M, Chu Y, et al. Human pulses reveal health conditions by a piezoelectret sensor via the approximate entropy analysis. Nano Energy 2019; 58: 528-35.
11. Wang YJ, Chen CH, Sue CY, Lu WH, Chiou YH. Estimation of blood pressure in the radial artery using strain-based pulse wave and photoplethysmography sensors. Micromachines (Basel) 2018; 9: 556.
12. Castaneda D, Esparza A, Ghamari M, Soltanpur C, Nazeran H. A review on wearable photoplethysmography sensors and their potential future applications in health care. Int J Biosens Bioelectron 2018; 4: 195-202.
13. Li JQ, Li R, Chen ZZ, et al. Design of a continuous blood pressure measurement system based on pulse wave and ECG signals. IEEE J Transl Eng Health Med 2018; 6: 1900114.
14. Li BN, Fu BB, Dong MC. Development of a mobile pulse waveform analyzer for cardiovascular health monitoring. Comput Biol Med 2008; 38: 438-45.
15. Li C, Xiong H, Pirbhulal S, et al. Heart-carotid pulse wave velocity a useful index of atherosclerosis in Chinese hypertensive patients. Medicine (Baltimore) 2015; 94: e2343.
16. Li C, Xiong H, Wu W, et al. The relationship between heart-carotid pulse transit time and carotid intima-media thickness in hypertensive patients. J Hum Hypertens 2015; 29: 663-8.
17. Nelson MR, Stepanek J, Cevette M, Covalciuc M, Hurst RT, Tajik AJ. Noninvasive measurement of central vascular pressures with arterial tonometry: clinical revival of the pulse pressure waveform? Mayo Clin Proc 2010; 85: 460-72.
18. Pauca AL, O'Rourke MF, Kon ND. Prospective evaluation of a method for estimating ascending aortic pressure from the radial artery pressure waveform. Hypertension 2001; 38: 932-7.
19. Zhao ZQ, Zheng GW, Pang Y, Sheng W, Liao C, Lin JZ. Study on pulse wave signal noise reduction and feature point identification. J Convergence Inf Technol 2013; 8: 953-60.
20. Waugh W, Allen J, Wightman J, Sims AJ, Beale TAW. Novel signal noise reduction method through cluster analysis, applied to photo-plethysmography. Comput Math Methods Med 2018; 2018: 6812404.
21. Kohara K, Tabara Y, Oshiumi A, Miyawaki Y, Kobayashi T, Miki T. Radial augmentation index: a useful and easily obtainable parameter for vascular aging. Am J Hypertens 2005; 18: 11s-4s.
22. Takazawa K, Kobayashi H, Shindo N, Tanaka N, Yamashina A. Relationship between radial and central arterial pulse wave and evaluation of central aortic pressure using the radial arterial pulse wave. Hypertens Res 2007; 30: 219-28.
23. Yang TH, Jo G, Koo JH, Woo SY, Kim JU, Kim YM. A compact pulsatile simulator based on cam-follower mechanism for generating radial pulse waveforms. Biomed Eng Online 2019; 18: 1.
24. Jeong JH, Lee B, Hong J, Yang TH, Park YH. Reproduction of human blood pressure waveform using physiology-based cardiovascular simulator. Sci Rep 2023; 13: 7856.
Outlines

/